View Issue Details

IDProjectCategoryView StatusLast Update
000347810000-004: ServicesSpecpublic2016-12-15 23:22
ReporterThomas Merk Assigned ToMatthias Damm  
PrioritynormalSeverityminorReproducibilityhave not tried
Status closedResolutionfixed 
Summary0003478: StatusCode.InfoBits are defined but nowhere referenced.
Description

The description says:
NotUsed 00 The info bits are not used and shall be set to zero.
DataValue 01 The StatusCode and its info bits are associated with a data value
returned from the Server. This flag is only used in combination with
StatusCodes defined in Part 8.
Reserved 1X Reserved for future use. The info bits shall be ignored.

So the only real value would be "01" - DataValue.
However nowhere in Part 8 DataValue bit(s) are mentioned.

From my point of view these bits can be treated as "reserved".

TagsNo tags attached.
Commit Version
Fix Due Date

Activities

Jim Luth

2016-08-30 16:36

administrator   ~0007168

InfoBits are used in other places, not just with status codes defined in Part 8.
Remove the statement that implies this.

Matthias Damm

2016-12-12 07:19

developer   ~0007509

Replaced
This flag is only used in combination with StatusCodes defined in Part 8.
With
The info bites are defined in Table 173.

Made changes in document version OPC UA Part 4 - Services 1.04 Specification Draft 02.docx

Jim Luth

2016-12-15 23:22

administrator   ~0007600

Agreed to changes in meeting.

Issue History

Date Modified Username Field Change
2016-07-21 12:17 Thomas Merk New Issue
2016-08-30 16:36 Jim Luth Note Added: 0007168
2016-08-30 16:36 Jim Luth Target Version => 1.04
2016-08-30 16:36 Jim Luth Assigned To => Matthias Damm
2016-08-30 16:36 Jim Luth Status new => assigned
2016-12-12 07:19 Matthias Damm Note Added: 0007509
2016-12-12 07:19 Matthias Damm Status assigned => resolved
2016-12-12 07:19 Matthias Damm Resolution open => fixed
2016-12-15 23:22 Jim Luth Note Added: 0007600
2016-12-15 23:22 Jim Luth Status resolved => closed
2016-12-15 23:22 Jim Luth Fixed in Version => 1.04