View Issue Details

IDProjectCategoryView StatusLast Update
000185510000-009: Alarms and Conditionspublic2012-01-27 16:57
ReporterMatthias Damm Assigned ToPaul Hunkar  
PrioritynormalSeverityminorReproducibilityalways
Status closedResolutionfixed 
Summary0001855: Reporting bad status for event fields only if Retain==True?
Description

The latest clarifications for connection problems to underlying systems do not talk about the affected conditions.

I think we discussed that only conditions where Retain==True do trigger new events where the affected event fields are set to Bad_NoCommunication.

There is one reference in 5.14.1 Communication problems but it is not clearly stated there.

Should be clarified in

  • 5.5.2 ConditionType -> Quality
  • 5.14.1 Communication problems

In addition the new chapter 5.14.1 Communication problems needs some English review. Several sentences make no sense or are incomplete.

TagsNo tags attached.
Commit Version
Fix Due Date

Activities

Paul Hunkar

2012-01-27 16:53

developer   ~0003244

Fixed text as needed

Jim Luth

2012-01-27 16:57

administrator   ~0003245

Reviewed and agreed after final editing in telecon.

Issue History

Date Modified Username Field Change
2012-01-24 23:52 Matthias Damm New Issue
2012-01-24 23:52 Matthias Damm Status new => assigned
2012-01-24 23:52 Matthias Damm Assigned To => Paul Hunkar
2012-01-27 16:53 Paul Hunkar Status assigned => resolved
2012-01-27 16:53 Paul Hunkar Resolution open => fixed
2012-01-27 16:53 Paul Hunkar Note Added: 0003244
2012-01-27 16:57 Jim Luth Status resolved => closed
2012-01-27 16:57 Jim Luth Note Added: 0003245